Video Reviews
###<iframe width="610" height="340" src="https://www.youtube.com/embed/7cFZTsj4VPY?si=bWLSd5kI6hhVgLxw" frameBorder="0" allow="clipboard-write; autoplay" webkitAllowFullScreen mozallowfullscreen allowFullScreen></iframe>###
Description
Digital camera
The MAGUS CLM30 digital camera is designed for use in fluorescence and darkfield microscopy techniques. The high-sensitivity SONY Exmor CMOS sensor with low noise levels ensures reliable fluorescence visualization even at low fluorescence intensity.
A two-stage thermoelectric cooling module effectively reduces thermal noise during long exposures.
High light sensitivity combined with low noise allows for a wide range of exposure times, from fractions of a millisecond up to one full hour. This makes the camera versatile for many microscopy techniques: brightfield, darkfield, polarization, and fluorescence.
The 1/1.2” 8.3MP sensor delivers detailed images at 3840x2160 resolution.
The camera supports high-resolution photo and video capture, including 4K, and connects via USB 3.0 for fast data transfer and smooth real-time operation. All imaging parameters are controlled through the MAGUS View software, which gives you precise control over exposure and image brightness.
The MAGUS CLM30 is mounted in the trinocular tube using a C-mount adapter.
Microscope head
Trinocular head with infinity-corrected optics. The eyepiece tubes are raised or lowered by rotating the head around the axis. The user can adjust the eyepiece height to suit their individual stature.
The digital camera is mounted in the trinocular tube. The beam splitting ratio is fixed at 50/50.
The vertical tube provides 0.55x magnification. When paired with the included 1x adapter, the final magnification at the camera is 0.55x. When calculating the field of view and on-screen magnification for each objective, use a total factor of 0.55x.
The basic configuration includes 10x/22mm eyepieces with diopter adjustment and high eyepoint for working with glasses. Flat rubber eyecups protect eyeglasses from scratches.
Revolving nosepiece and objectives
The coded revolver for five objectives is oriented toward the interior: The user can see the objective inserted into the optical path, and the space above the stage is free. An additional objective can also be installed in the free slot in order to achieve extra magnification. The parfocal distance is 60mm.
The 40x objective with its extended working distance of 1.5mm provides additional protection for the front lens against immersion oil contact when rotating the nosepiece.
Above the revolver, there is a slot with a plug for installing the analyzer.
Maintaining a comfortable brightness level in transmitted light when changing magnifications
The objectives of different magnifications transmit light with different levels of intensity, and so each time you change objectives, the brightness of the light must be adjusted. Switching from a higher to a lower magnification objective causes eye fatigue, as the image brightness in the eyepieces increases sharply. The MAGUS Lum D450L, which is equipped with intelligent brightness control, solves this problem. The microscope remembers the brightness for each objective that the user has selected and automatically sets this brightness when turning the nosepiece. Intelligent control reduces the time required to adjust brightness. MAGUS Lum D450L increases user comfort and saves you time even when your work requires frequent magnification changes.
Focusing mechanism
Coaxial coarse and fine focusing knobs.
The coarse focusing knob is located on the left side. Fine focusing knobs are located on both sides, the right knob having special finger indentations.
The ring on the left side adjusts the tension of the coarse focusing travel. The user adjusts the comfortable tension for work.
Stage
The stage has no X-axis rack and pinion, which improves ergonomics. The belt-driven mechanism allows for smooth movement of the specimen. The specimen holder is secured with two screws and can be easily removed during manual scanning.
The long stage control handle ensures user comfort: The hand rests on the table with no strain.
Epi-fluorescence illuminator
The fluorescence excitation light source: 3W LEDs, filters of two wavelengths: blue (B) and green (G). Setting the switch on the reflected light illuminator to the left or right position, you choose the desired filter. The central position of the switch corresponds to the brightfield observations.
The LEDs instantly reach the brightness that is set by the user. They do not heat up during prolonged use and can switch off quickly, if necessary. This makes it easy to switch from the brightfield technique to fluorescence and back again. The LED lifetime is 50,000 hours. It is recommended to choose LED-based fluorescence for higher education as it is the safest option and requires minimal maintenance.
Köhler illumination in transmitted light
Setting up the Köhler illumination enhances the image quality of a specimen. With such illumination, you achieve maximum resolution on each objective. Even illumination of the field of view with no darkening at the edges. The object of study is in sharp focus and the image artifacts are removed.
Condenser
The condenser is height-adjustable and can be centered. Mounting type: dovetail.
The condenser ring adjusts the iris aperture diaphragm. The condenser body has a marking for the magnification of the objectives, and the ring has an indicator marker. To achieve contrast on each objective, it is recommended to rotate the ring so that the index marker matches the magnification marking of the objective being used.
The condenser has a slot with a plug for a darkfield slider or a phase contrast slider. The installation of a slider saves time when changing the observation method.
Transmitted light source
The transmitted light illuminator uses a 3W LED. The color temperature does not change when you adjust the brightness. The LED lifetime is 50,000 hours.
Status LCD screen
The LCD screen on the base of the microscope displays the objective magnification, brightness and color temperature of the light source, and operating mode (“sleep” and “eco”).
The screen and a single knob allow the user adjust the brightness, lock the brightness adjustment, set the Sleep mode and the auto-off timer.
Ergonomic design
Physical discomfort causes fatigue and reduces productivity. The ergonomic design of the microscope plays an important role in everyday scientific research.
MAGUS Lum D450L provides user comfort during operation.
By rotating the microscope head, the user selects a point of view height so as not to strain their back and neck.
Focusing knobs are located at the bottom of the body. The user does not need to strain their hands. Thanks to the smooth movement of the mechanism, the user can effortlessly focus on the object.
The microscope is operated with minimal hand movement, since the stage control knob and fine focusing knob are located in the same working area.
The microscope is equipped with a special carrying handle.
The design for the hidden placement of the power cord improves the workplace esthetic and safety of carrying the microscope as well as simplifies storage of the device.
Accessories
There is a line of accessories designed specifically for this microscope.
Optional objectives provide additional magnification.
Eyepieces extend the magnification range of the microscope. Optional eyepieces help you maximize the potential of the objective that you use most often.
The phase contrast device, darkfield slider, and polarizer/analyzer set offer more contrast techniques so that you can study specimens that are invisible in brightfield.
A calibration slide is used to measure objects and can be combined with the eyepiece with a scale or with the camera software.
Alternative models
The MAGUS Lum D450L is an alternative for the following models: Carl Zeiss Primo Star iLED, Nikon ECLIPSE Si.
Key features
Microscope features:- Study of specimens emitting fluorescence when exposed to excitation light
- Microscopy techniques: fluorescence in reflected light, brightfield in transmitted light
- The trinocular head with a vertical tube for installing a digital camera and height adjustment to adjust to the observer; light beam splitting 50/50
- Coded revolving nosepiece: The brightness of the light source is set automatically depending on the selected objective
- Reflected light illuminator: two 3W LEDs with different wavelengths
- Visible fluorescence excitation filters: blue (B) and green (G)
- Transmitted light illuminator: energy‑saving 3W LED with a lifetime of up to 50,000 hours
- Köhler illumination in transmitted light
- Centerable and height-adjustable condenser with objective magnification markings
- Smart transmitted light control system: automatic brightness selection, brightness adjustment lock, auto-off timer, LCD operating status screen
- Stage without an X-axis positioning rack, featuring a long control handle for convenient operation
- Ergonomic stand with a carrying handle and the hidden placement of the power cord
- Wide range of compatible optional accessories
Camera features:- For fluorescence and darkfield microscopy with 4x, 10x, 20x, and 40x objectives
- 8.3MP resolution: When observing with low magnification objectives, the camera will allow you to see finer details
- 45fps and 70fps at 3840x2160px and 1920x1080px resolutions for observing moving samples, recording video, and moving the preparation without jerks and delays
- Peltier element reduces the sensor temperature during prolonged operation and eliminates thermal noise. Therefore, long shutter speeds can be used when taking photos
- SONY Exmor color CMOS backlit sensor provides a low noise level and high light sensitivity even in low-light conditions. You will get clearer, brighter, and more color-saturated images
- USB 3.0 interface for fast data transfer with no jerking or lagging
- Software with functions for taking photos, recording video, editing, displaying images on an external screen, and measuring linear and angular dimensions
Package
- MAGUS CLM30 digital camera (digital camera, USB cable, 12V, 3A power adapter, carrying case, USB flash drive with drivers and software, user manual, and warranty card)
- Stand with a built-in power supply, reflected light illuminator for visible fluorescence, transmitted light source, focusing mechanism, stage, condenser mount, and revolving nosepiece
- Abbe condenser
- Epi-fluorescence attachment
- Trinocular microscope head
- Plan achromatic objective Plan 4x/0.10 ∞/–, parfocal distance: 60mm
- Plan achromatic objective Plan 10x/0.25 ∞/–, parfocal distance: 60mm
- Plan achromatic objective Plan 40x/0.65 ∞/0.17, parfocal distance: 60mm
- Plan achromatic objective Plan 100x/1.25 oil ∞/0.17 (spring-loaded), parfocal distance: 60mm
- 10х/22mm eyepiece with high eyepoint and diopter adjustment (2 pcs.)
- Eyecup (2 pcs.)
- C-mount adapter
- Microscope power cord
- Power adapter for a fluorescence attachment
- Dust cover
- User manual and warranty card
Available on request:- 10х/22mm eyepiece with a scale
- 10x/22mm eyepiece with a reticle
- 10x/22mm eyepiece with crosshairs
- 12.5х/16mm eyepiece (2 pcs.)
- 15х/16mm eyepiece (2 pcs.)
- 20х/12mm eyepiece (2 pcs.)
- 30х/8mm eyepiece (2 pcs.)
- Plan achromatic objective Plan 2х/0.06 ∞/–, parfocal distance: 60mm
- Plan achromatic objective Plan 20х/0.40 ∞/0.17, parfocal distance: 60mm
- Plan achromatic objective Plan 60х/0.80 ∞/0.17, parfocal distance: 60mm
- Plan apochromatic objective Plan Apo 60х/1.42 oil ∞/0.17, parfocal distance: 60mm
- Plan achromatic objective Plan 100х/1.10 ∞/0.17 water, parfocal distance: 60mm
- Set of plan semi-apochromatic fluorescence objectives: 4x, 10x, 20x, 40x, 100x (oil); ∞/0.17; parfocal distance 60mm
- Phase contrast device: set of phase sliders, set of phase objectives, centering telescope
- Phase contrast device: phase contrast condenser, set of phase objectives, auxiliary centering telescope
- Darkfield slider
- Dry darkfield condenser NA 0.7–0.9
- Oil darkfield condenser NA 1.3–1.26
- Polarizer/analyzer set
- Stage plate, black
- Calibration slide
- Set of color filters (blue, green, yellow, frosted glass)
- C-mount adapter
- Monitor and digital camera with an HDMI interface
Microscope specifications
Microscope design: upright
Image field: flat
Reflected light microscopy techniques: fluorescence
Transmitted light microscopy techniques: brightfield, darkfield (optional), polarized light (optional), phase contrast (optional)
Microscope magnification, x: 40–1000 basic configuration (optional: 40–1250/1500/2000)
Tube length: infinity (∞)
Microscope head: trinocular
Beam splitting ratio (eyepieces/trinocular tube): fixed, 50/50
Microscope head: Gemel head (Siedentopf, 360° rotatable)
C-mount adapter, vertical tube: 0.55x
Inclination: 30°
Microscope head magnification, x: 1
Interpupillary distance, mm: 47–78
Eyepiece diameter, mm: 30
Eyepieces, x/field, mm: 10x/22 with diopter adjustment ± 5dp, high eyepoint (optional: 10x/22 with a scale, 10x/22 with a reticle, 10x/22 with crosshairs, 12.5x/16, 15x/16, 20x12, 30х8)
Revolving nosepiece: 5 objectives, coded
Optical design: infinity plan achromatic objectives (∞), parfocal distance: 60mm
Objectives, x/aperture/working distance, mm: 4x/0.10/30; 10x/0.25/10.2; 40x/0.65/1.5; 100x/1.25 oil/0.2(optional: 2x/0.06; 20x/0.40; 60x/0.80; 100x/1.10 (water); Plan Apo 60x/1.42 (oil); set of plan semi-apochromatic fluorescence objectives 4x/10x/20x/40x/100x (oil))
Spring-loaded retractable assembly: 60x, 100x
Stage: 230х150mm, rackless XY mechanical stage
Moving range, mm: 78/54
Condenser: centerable and height-adjustable Abbe condenser NA 1.25 with an adjustable aperture diaphragm and a slot with a plug for a darkfield or phase contrast slider; dovetail mount
Field diaphragm: adjustable iris
Focusing mechanism: coaxial coarse & fine focusing knobs; coarse focusing knob on the left side; fine focusing knobs on both sides
Coarse focusing travel, mm: 30
Coarse focusing travel, mm/circle: 37.7
Fine focusing travel, mm/circle: 0.2
Fine focusing scale value, μm: 2
Coarse focusing tension adjusting knob: +
Coarse focusing lock knob: +
Illumination method: transmitted and reflected light
Reflected light source: 3W LED
Transmitted light source: 3W LED
Intelligent lighting control system: automatic brightness adjustment in transmitted light during objective change, status display on LCD screen, standby mode, eco-mode
Fluorescence filters: filter type, excitation wavelength / dichroic mirror / emission wavelength: blue (B), 460–495nm / 505nm / 510nm;
green (G), 510–550nm / 570nm / 575nm
Phase contrast technique: optional: 10x–40x phase-contrast slider; 100x phase-contrast slider; phase-contrast objectives (10х, 20х, 40х, 100х); centering telescope
phase-contrast turret condenser; phase-contrast objective (10x, 20x, 40x, 100x); centering telescope
Darkfield condenser: optional: darkfield slider, dry darkfield condenser NA 0.7–0.9 (for dry objectives), oil darkfield condenser NA 1.3–1.26 (for 100x immersion objective)
Fluorescence technique: epi-fluorescence attachment with LED light source
Polarizer/analyzer set: optional: polarizer mounted on the collector; analyzer in the slot of the stand above the revolving nosepiece
Power supply, V/Hz: AC power supply, 100–240 / 50/60
Operating temperature range, °C: 0… 40
Operating humidity range, %: 0… 80 (up to 31 °C)
Camera specifications
Sensor: SONY Exmor CMOS
Color/monochrome: color
Number of megapixels: 8.3
Maximum resolution, px: 3840x2160
Sensor size: 1/1.2" (11.14x6.26mm)
Pixel size, µm: 2.9x2.9
Two-stage thermoelectric module (Peltier element) to set the temperature 42°C below room temperature: +
Light sensitivity: 5970mV with 1/30s
Signal/noise ratio: 0.15mV with 1/30s
Exposure: 0.1ms–1h
Video recording: +
Frame rate, fps at resolution, px: 45@3840x2160, 70@1920x1080
ADC digit capacity, bit: 8/12 (switchable)
Mounting location: trinocular tube
Image format: *.jpg, *.bmp, *.png, *.tif
Video format: *.wmv, *.avi, *.h264 (Win 8 or above), *.h265 (Win 10 or above)
Spectral range, nm: 380–650 (IR-filtered)
Shutter type: ERS (electronic rolling shutter)
White balance: auto/manual
Exposure control: auto/manual
Software features: image size, brightness, exposure
Port: USB 3.0, 5Gbps
System requirements: Windows 8/10/11 (32bit and 64 bit), Mac OS X, Linux, up to 2.8GHz Intel Core 2 or higher, minimum 2GB RAM, USB 3.0 port, CD-ROM, 17” or larger display
Software: MAGUS View
Mount type: C-mount
Body: cast aluminum
Power supply: DC 5V, from the USB port of the computer; 12V/3A power supply adapter for the Peltier thermoelectric cooler
Operating temperature range, °C: –10... 50
Operating humidity range, %: 30… 80