Description
Digital camera
MAGUS CBF70 is a science camera with 21MP resolution and 4/3" sensor for the brightfield microscopy technique.
The camera delivers a realistic image at a 5280x3954 pix resolution. The camera is recommended for use with 4x, 10x, 20x, and 40x objectives. When working with low magnification objectives, the camera will allow you to see finer details.
At maximum resolution, video is captured at 17fps. It is enough for adjusting the focusing of the microscope.
When the resolution is reduced, the rate increases to 56, 67, and 192fps. Transitions between frames become softer, the camera catches the slightest movement of the sample. These modes are suitable for classroom demonstrations, recording video of fast-moving processes, and observing samples that are moving.
The camera is equipped with a USB 3.0 interface. The data transfer speed is 10 times faster than USB 2.0 cameras. The high-speed camera is recommended for professional laboratories, research, or university training.
Microscope head
Trinocular head with infinity plan achromatic objectives. Digital image capturing devices are mounted in the trinocular tube. The eyepiece/camera light path selection knob allows you to direct the light beam to either the digital camera or the eyepiece tubes.
The diopter adjustment is on the left tube.
Revolving nosepiece
Five objectives. A free slot is used for centering the light source. An additional objective can also be installed in a free slot in order to achieve extra magnification. The design of the revolving nosepiece (“away from the observer”) frees up space at the front of the stage and, therefore, the user can see the objective inserted into the optical path. The revolving nosepiece slots are centered to align the optical axis of the objective and microscope.
Objectives
Infinity plan achromatic objectives are designed specifically for polarized light observations: The strain-free optics ensure that the birefringence comes from the specimen and not from the optical elements. The objectives are designed to study samples without cover slips.
Focusing mechanism
Coaxial coarse and fine focusing knobs are located at the bottom of the stand on both sides. The user can place their hands on the table and take a relaxed pose while observing. The focusing adjustment is smooth and effortless.
The design of the focusing mechanism provides for quick microscope adjustment after changing the object of study. For this purpose, a coarse focusing lock knob is located on the right side. The coarse tension can be adjusted by turning the ring on the left side.
Stage
The stage rotates 360° to view the color change of the sample when the polarizer and analyzer are in crossed orientation. The stage has a gradation of the rotation angle. With the vernier scale, measurements are made with an accuracy of 0.1°.
The stage can be centered with two screws because the analysis of an anisotropic object in polarized light requires the precise alignment of the rotation axis of the stage with the optical axis of the microscope.
Light source
30W halogen bulbs are used in both reflected and transmitted light illuminators. Halogen bulbs emit light with a color temperature that allows for comfortable work. The 30W bulb is bright enough for you to observe with the 4x to 100x magnification objectives that are used for brightfield and polarized light microscopy.
Reflected light illumination
The illumination system makes it possible to set up the Köhler illumination. The field and aperture diaphragms are pre-centered at the factory and require no additional centering. If necessary, the diaphragms can be adjusted with centering screws. The light source is centered along three axes. The removable analyzer and polarizer are for the polarization microscopy technique. The polarizer rotates 0–360°, the analyzer rotates 360°, and the vernier scale on the analyzer provides accurate angle measurement.
A set of filters can help you adjust the color reproduction.
Transmitted light illumination
Köhler illumination: adjustable field diaphragm; centered and height-adjustable Abbe condenser with adjustable aperture diaphragm and swivel auxiliary lens. NA = 1.25. The polarizer is 0–360° rotatable, with four rotation angles of 0°, 90°, 180°, 270° marks on the scale. The analyzer rotates 360°, the vernier scale on the analyzer provides accurate angle measurement.
Köhler illumination in reflected and transmitted light
The Köhler illumination setup enhances the image quality of a specimen. With such illumination, you can achieve maximum resolution on each objective and uniform illumination of the field of view with no darkening at the edges. The object of study is in sharp focus, and the image artifacts are removed.
Studying samples in polarized light
The intermediate tube holds the analyzer and Bertrand lens, and it has a slot for compensators. The analyzer is inserted into the light path to observe objects in polarized light. When the polarizer and analyzer rotate, the polarization angle changes. You can achieve a mutually perpendicular position by setting both filters to the “0” position. When the microscope stand is rotated, depending on the polarization angle, the surface of the sample reflects light differently. The Bertrand lens is used for conoscopic studies. The compensators are designed to enhance the contrast of samples with weak birefringence.
Accessories
There is a line of accessories designed for the microscope.
Additional objectives can be used for studying objects up to 0.32µm.
Eyepieces extend the magnification range of the microscope. Additional eyepieces will help to utilize the full potential of an objective that is used more often.
A digital camera that outputs the microscope image on a monitor, stores files, and that has software that takes real-time measurements of specimens. A calibration slide for measuring objects that can be combined with an eyepiece with a scale or the camera software.
Key features
Key features of the microscope:- Studies of transparent and opaque anisotropic samples in polarized and natural light
- Powerful 30W halogen transmitted and reflected light source that provides bright natural light
- Bertrand lens for conoscopy and orthoscopy, compensators, and Köhler illumination in transmitted and reflected light
- Trinocular head with a trinocular tube for mounting a digital camera; 100:0 and 0:100 beam splitting
- Plan achromatic strain-free objectives eliminate the false optic effects
- Convenient alignment of the revolving nosepiece slots and stage
- Rotatable round stage with the vernier scale for precise angle measurement
- Wide range of optional accessories
Key features of the camera:- For brightfield microscopy observations with 4x, 10x, 20x, and 40x objectives
- 21MP resolution: When working with low magnification objectives, the camera will allow you to see finer details
- 17fps at maximum resolution is enough for focusing adjustment
- Up to 192fps at reduced resolution for classroom demonstrations, observation of moving samples, video recording; movement of a sample can be seen without jerkiness or delays
- SONY Exmor backlit color CMOS sensor provides low noise level and high light sensitivity even in low-light conditions. You will get clearer, brighter, and more color-saturated images
- USB 3.0 interface for fast, smooth data transfer
- Software with photo, video recording, editing, external display, and linear and angular measurement
Package
- MAGUS CBF70 Digital Camera (digital camera, USB cable, installation CD with drivers and software, user manual and warranty card)
- Base with a power input, transmitted light source and condenser, focusing mechanism, stage, and revolving nosepiece
- Reflected light illuminator with a lamphouse
- Trinocular head
- Intermediate tube with Bertrand lens, an analyzer and compensator slot
- Compensators: λ compensator, λ/4 compensator, quartz wedge
- Infinity plan achromatic objective: PL 5x/0.12 WD 26.1mm
- Infinity plan achromatic objective: PL 10x/0.25 WD 5.0mm
- Infinity plan achromatic objective: PL 40x/0.6 (spring-loaded) WD 3.98mm
- Infinity plan achromatic objective: PL 60x/0.7 (spring-loaded) WD 2.03mm
- Eyepiece 10x/20 mm (2 pcs.)
- Eyepiece 10x/20mm with crosshairs
- C-mount adapter 1x
- Hex key wrench
- Power cord
- Dust cover
- User manual and warranty card
Available on request:- 10x/20mm eyepiece with a scale. Scale value: 0.1mm
- 16x/11mm eyepiece (2 pcs.)
- 20x/11mm eyepiece (2 pcs.)
- Infinity plan achromatic objective: PL 2.5x/0.07 WD 11mm
- Infinity plan achromatic objective: PL 50x/0.7 (spring-loaded) WD 3.67mm
- Infinity plan achromatic objective: PL 80x/0.8 (spring-loaded) WD 1.25mm
- Infinity plan achromatic objective: PL 100x/0.85 (spring-loaded) WD 0.4mm
- Mechanical stage attachment
- Calibration slide
Microscope specifications
Microscope design: upright
Image field: flat-field
Reflected light microscopy techniques: brightfield, polarized light
Transmitted light microscopy techniques: brightfield, polarized light
Microscope magnification, x: 50–600 basic configuration (*optional: 25–1000/1600/2000)
Tube length: infinity (∞)
Microscope head type: trinocular
Microscope head: Siedentopf
Inclination: 30°
Interpupillary distance, mm: 48–75
Eyepiece diameter, mm: 23.2
Diopter adjustment, diopters: ±5 (left eyepiece)
Eyepieces, x/field, mm: 10х/20; 10x/20 with crosshairs (*optional: 10x/20 with a scale; 16x/11; 20х/11)
Revolving nosepiece: for 5 objectives, centering
Optical design: infinity plan achromatic objectives, strain-free, parfocal height 45mm, designed for studying specimens without cover slips
Objectives, x/aperture/working distance, mm: PL 5x/0.12/26.1; PL 10x/0.25/5.0; PL 40x/0.6/3.98; PL 60x/0.7/2.03 (*optional: PL 2.5x/0.07/11; PL 50x/0.7/3.67; PL 80x/0.8/1.25; PL 100x/0.85/0.4)
Spring-loaded retractable assembly: 40x, 60x, 50x, 80x, 100x
Stage: Ø150mm, 360° rotatable; centering, 1° graduation of the rotation angle; a vernier scale for measuring angles with an accuracy of 0.1°
Focusing mechanism: coaxial coarse and fine focusing knobs located on both sides
Coarse focusing travel, mm: 21
Coarse focusing travel/circle: 39.8
Fine focusing scale value, μm: 2
Coarse focusing tension adjusting knob: +
Coarse focusing lock knob: +
Illumination: transmitted and reflected light
Reflected illumination: built-in field and aperture diaphragms, removable analyzer and polarizer; color filters: matt, yellow, green, blue
Reflected light source: 12V, 30W halogen bulb, brightness-adjustable
Transmitted light illumination: built-in field diaphragm, centered and height-adjustable Abbe condenser, NA 1.25, adjustable aperture diaphragm and swivel lens
Transmitted light source: 12V, 30W halogen bulb, brightness-adjustable
Transmitted light polarizer: with 0°, 90°, 180°, 270° marks on the scale; 360° rotatable
Intermediate tube: built-in analyzer, rotatable 0–360°; a vernier scale for measuring angles with an accuracy of 0.1°; Bertrand lens; slot for installing compensators
Compensator: λ compensator; λ/4 compensator; quartz wedge
Power supply, V/Hz: 220±22/50
Operating temperature range, °C (°F): 5… 35 (41… 95)
Operating humidity range, %: 20… 80
Camera specifications
Sensor: SONY Exmor CMOS
Color/monochrome: color
Megapixels: 21
Maximum resolution, pix: 5280x3954
Sensor size: 4/3" (17.4x13.0mm)
Pixel size, μm: 3.3x3.3
Light sensitivity: 399mV at 1/30s
Signal/noise ratio: 0.1mV at 1/30s
Exposure: 0.1ms–15 s
Video recording: +
Frame rate, fps at resolution: 17@5280x3954; 17@3952x3952; 56@2640x1976; 67@1760x1316; 192@584x438
Place of installation: trinocular tube, eyepiece tube instead of eyepiece
Image format: *.jpg, *.bmp, *.png, *.tif
Video format: recording: *.wmv, *.avi, *.h264 (Win 8 or newer), *h265 (Win 10 or newer)
Spectral range, nm: 380–650 (with IR filter)
Shutter type: ERS (electronic rolling shutter)
White balance: auto/manual
Exposure control: auto/manual
Software features: image size, brightness, exposure time
Output: USB 3.0, 5Gb/s
System requirements: Windows 8/10/11 (32 and 64 bit), Mac OS X, Linux, up to 2.8GHz Intel Core 2 or higher, minimum 2GB RAM, USB3.0 port, CD-ROM, 17" or larger display
Software: MAGUS View
Mount type: C-mount
Body: solid aluminum
Power supply: DC current, 5V, with the USB port of the PC
Operating temperature range, °C: –10... 50 (14… 122)
Operating humidity range, %: 30… 80