MAGUS Metal VD700 BD

83038
7699,95
MAGUS Metal VD700 BD Metallurgical Inverted Digital Microscope
With a camera. Magnification: 50–500х. Trinocular head, plan achromatic objectives for darkfield and brightfield microscopy, 50W halogen reflected light illuminator

The microscope is designed for studying the microstructure of metals and alloys, semiconductor materials, and other opaque specimens. The design of the inverted microscope does not limit the size of the examined sample, only its weight is limited up to 2kg. The specimen must be first specially processed, and then it is placed on the stage with the surface down. This microscope can study opaque objects in reflected light using the brightfield, darkfield, and polarization microscopy techniques. The trinocular tube and a camera side port enable the simultaneous connection of a monitor and camera. The microscope can be used in various fields (metallurgical, engineering, aerospace, nuclear, and energy industries) as well as in research laboratories and technical universities.
Description
Key features
Package
Microscope specifications
Camera specifications
References and downloads

Description

Digital camera
The MAGUS CLM30 digital camera is designed for use in fluorescence and darkfield microscopy techniques.
The camera is equipped with an 8.3MP sensor and produces realistic images at a resolution of 3840x2160px. The camera is recommended for use with 4x, 10x, 20x, and 40x objectives. When working with low magnification objectives, the camera will allow you to see finer details.
Video is recorded at 45fps or 70fps depending on its resolution: They are smooth with soft and subtle transitions between frames. The movement of the sample is displayed in real time with no delays. The camera makes it easy to work with objects that are moving and is suitable for classroom demonstrations.
The camera is equipped with a USB3.0 interface. The data transfer speed is 10 times faster than USB2.0 cameras. The high-speed camera is recommended for professional laboratories, research, or university training.

Microscope head
Tube length – infinity (∞). When assembling the microscope, the user can rotate the eyepiece tubes 180° and adjust the eye relief to fit their height. There is a trinocular head. The monitor is mounted in the trinocular tube of the trinocular head and the digital camera – in the camera side port. The trinocular head is equipped with an 50:50 and 100:0 beam splitter, and there is a 2-position beam splitter (100:0/ 0:100) on the body.

Revolving nosepiece
The 5-objectives revolving nosepiece is mounted on the stand under the stage. A free slot is used for adjusting the position of the reflected light illuminator. An additional objective can also be installed in the free slot to achieve extra magnification.

Objectives
Plan achromatic objectives with a long working distance that is designed for the brightfield and darkfield microscopy techniques.

Focusing mechanism
Coaxial coarse and fine focusing knobs are located at the base of the microscope on both sides. The user can place their hands on the table and take a relaxed pose while observing. The focus adjustment is smooth and effortless. On the right, there is the coarse focusing lock knob for quick adjustments after changing the sample. On the left side, there is the focusing tension adjusting ring.

Mechanical stage
The object is moved by moving the stage along two axes. A round rotating stage plate with a hole of suitable diameter (10mm, 20mm, or 30mm) is installed in the center of the table. A specimen holder is used to hold the object in place.

Light source
The lamphouse has a 50W halogen bulb. It is bright enough to observe with 4x to 100x objectives used for brightfield, darkfield, and polarized light microscopy. The halogen bulb emits light with a color temperature that allows for comfortable work.

Reflected light illumination
The illumination system makes it possible to set up the Köhler illumination. The field and aperture diaphragm are pre-centered at the factory and require no additional centering. If necessary, the diaphragms can be adjusted with centering screws. The light source is centered along three axes. The removable analyzer and polarizer are for the polarization microscopy technique. The polarizer rotates 0–360°, but the analyzer does not rotate. A set of filters can help you adjust the color reproduction. The darkfield device is mounted in the stage.

Accessories
Additional accessories increase the technical performance of the microscope. Eyepieces and objectives extend the range of magnification. Digital cameras output the image to a computer screen or monitor. Calibration slides help you take measurements of objects.

Key features

Key features of the microscope:
  • Suitable for studying opaque dimensional objects up to 2kg
  • Trinocular head with the option to adjust eye relief
  • Two options for mounting a digital camera and monitor: trinocular tube of the trinocular head and camera side port on the body; beam splitting on the trinocular head 50:50 and 100:0, beam splitting on the body 100:0/0:100
  • Plan achromatic objectives with a long working distance that is designed for the brightfield and darkfield microscopy techniques
  • Reflected light illuminator with the powerful 50W bulb for darkfield microscopy
  • Köhler illumination, centered elements of the illumination system, darkfield, brightfield, and polarization microscopy
  • Filters reduce the intensity of certain wavelengths and adjust the color reproduction in microscope photography
  • Large-sized stage with round rotating stage plate with 10mm, 20mm, and 30mm holes
  • Large selection of additional eyepieces and objectives

Key features of the camera:
  • For fluorescence and darkfield microscopy with 4x, 10x, 20x, and 40x objectives
  • 8.3MP resolution: When observing with low magnification objectives, the camera will allow you to see finer details
  • 45fps and 70fps at 3840x2160px and 1920x1080px resolutions for observing moving samples, recording video, and moving the preparation without jerks and delays
  • Peltier element reduces the sensor temperature during prolonged operation and eliminates thermal noise. Therefore, long shutter speeds can be used when taking photos
  • SONY Exmor color CMOS backlit sensor provides a low noise level and high light sensitivity even in low-light conditions. You will get clearer, brighter, and more color-saturated images
  • USB3.0 interface for fast, smooth data transfer
  • Software with photo, video recording, editing, external display functions, linear and angular measurements

Package

  • MAGUS CLM30 Digital Camera (digital camera, USB cable 12V, 3A adapter, case, Installation CD with drivers and software, user manual and warranty card)
  • Base with a power input, focusing mechanism, stage and revolving nosepiece
  • Lamphouse
  • Trinocular head
  • Infinity plan achromatic objective: PL L5x/0.12 BD WD 9.7mm
  • Infinity plan achromatic objective: PL L10x/0.25 BD WD 9.3mm
  • Infinity plan achromatic objective: PL L20x/0.40 BD WD 7.2mm
  • Infinity plan achromatic objective: PL L50х/0,70 BD WD 2.5mm
  • Eyepiece 10x/22mm with eye relief (2 pcs.)
  • C-mount adapter 1x
  • Hex key wrench
  • AC power cord
  • Dust cover
  • User manual and warranty card

Available on request:
  • 10x/22mm eyepiece with a scale
  • 12.5x/14mm eyepiece (2 pcs.)
  • 15x/15mm eyepiece (2 pcs.)
  • 20x/12mm eyepiece (2 pcs.)
  • 25x/9mm eyepiece (2 pcs.)
  • Infinity plan achromatic objective: PL L40x/0.60 BD WD 3.0mm
  • Infinity plan achromatic objective: PL L60x/0.70 BD WD: 1.9mm
  • Infinity plan achromatic objective: PL L80x/0.80 BD WD: 0.8mm
  • Infinity plan achromatic objective: PL L100х/0.85 (dry) BD WD: 0.4mm
  • Digital camera
  • Calibration slide

Microscope specifications

Microscope design: inverted

Image field: flat-field

Reflected light microscopy techniques: brightfield, darkfield, polarized light

Microscope magnification, x: 50–500 basic (*optional: 50–1000/1250/1500/2000/2500)

Tube length: infinity (∞)

Microscope head type: trinocular

Microscope head: Siedentopf, rotatable 180°

Inclination: 45°

Interpupillary distance, mm: 48–75

Eyepiece diameter, mm: 30

Eyepieces, x/field, mm: 10х/22mm, eye relief: 10mm (*optional: 10x/22mm with a scale, 12.5x/14; 15x/15; 20x/12; 25x/9)

Revolving nosepiece: 5 objectives

Optical design: infinity plan achromatic objectives (∞), parfocal distance: 45mm

Objectives, illumination technique: darkfield

Objectives, x/aperture/working distance, mm: PL L5x/0.12/9.7 BD, PL L10x/0.25/9.3 BD, PL L20x/0.40/7.2 BD, PL L50x/0.70/2.5 BD (*optional: PL L40x/0.60/3.0 BD, PL L60x/0.70/1.9 BD, PL L80x/0.80/0.8 BD, PL L100x/0.85/0.4 BD (dry))

Mechanical stage: 242x200mm, two-axis mechanical stage; round rotating stage plate Ø13mm with holes Ø10mm, Ø20mm and Ø30mm

X- and Y-axis stage moving range, mm: 30/30

Focusing mechanism: coaxial coarse and fine focusing knobs located on both sides

Fine focusing scale value, μm: 2

Coarse focusing tension adjusting knob: +

Coarse focusing lock knob: +

Illumination: reflected light

Reflected light illuminator: darkfield device, built-in field and aperture diaphragms, removable analyzer and polarizer; color filters: matt, yellow, green, blue

Reflected light source: 12V, 50W halogen bulb, brightness-adjustable

Power supply, V/Hz: 220±22V/50Hz via an AC power supply

Operating temperature range, °C (°F): 5… 35 (41… 95)

Operating humidity range, %: 20… 80


Camera specifications

Sensor: SONY Exmor CMOS

Color/monochrome: color

Megapixels: 8.3

Maximum resolution, pix: 3840x2160

Sensor size: 1/1.2'' (11.14x6.26mm)

Pixel size, μm: 2.9x2.9

Two-stage thermoelectric module (Peltier element) to set the temperature 42°C below room temperature: +

Light sensitivity: 5970mV with 1/30s

Signal/noise ratio: 0.15mV with 1/30s

Exposure: 0.1ms–1h

Video recording: +

Frame rate, fps at resolution: 45@3840x2160; 70@1920x1080; ADC digit capacity (bit); 8/12 (selectable)

Place of installation: trinocular tube

Image format: *.jpg, *.bmp, *.png, *.tif

Video format: recording: *.wmv, *.avi, *.h264 (Win 8 or newer), *h265 (Win 10 or newer)

Spectral range, nm: 380-650 (with IR filter)

Shutter type: ERS (electronic rolling shutter)

White balance: auto/manual

Exposure control: auto/manual

Software features: image size, brightness, exposure time

Output: USB3.0, 5 Gb/s

System requirements: Windows 8/10/11 (32 and 64 bit), Mac OS X, Linux, up to 2.8GHz Intel Core 2 or higher, minimum 2GB RAM, USB3.0 port, CD-ROM, 17" or larger display

Software: MAGUS View

Mount type: C-mount

Body: CNC aluminum alloy

Power supply: DC, 5V, from computer USB port; a 12V, 3A adapter for Peltier element

Operating temperature range, °C (°F): –10... 50 (14… 122)

Operating humidity range, %: 30… 80