MAGUS Lum VD500

83020
10799,95
MAGUS Lum VD500 Fluorescence Inverted Digital Microscope
With a camera. Magnification: 100–400x. Trinocular head, plan achromatic objectives, reflected light source – 100W mercury lamp, transmitted light source – 30W halogen bulb, Köhler illumination

The microscope is intended for studying specimens using the fluorescence microscopy technique in reflected light and using the brightfield and phase contrast techniques in transmitted light.
The fluorescence microscopy is based on the ability of some substances to glow when exposed to light of a certain part of the spectrum. The specimens are exposed to invisible short-wave ultraviolet light or violet, blue, and green light. The wavelength of the emitted light will be longer than the wavelength of the excitation light. The specimen glows with blue, cyan, green-yellow, or red light, respectively. Some specimens glow by themselves while others glow after treatment with fluorochromes.
The microscope is used for the examination of liquid precipitates, cell colonies, living cells, tissue cultures, and other samples in nutrient medium in glassware up to 55mm with a bottom thickness of 1.2mm. The microscope uses special objectives for working with such glassware. The illuminator stand is tiltable for use with Petri dishes or flasks up to 165mm. The microscope is suitable for immunochemical diagnostics and chromosome analysis as well as the detection of latent bacterial and viral infections.
Description
Key features
Package
Microscope specifications
Camera specifications
References and downloads

Description

Digital camera
The MAGUS CLM90 digital camera is designed for use in fluorescence and darkfield microscopy techniques.
The camera is equipped with a 7.1MP sensor and produces realistic images at a resolution of 3200x2200px. The camera is recommended for use with 4x, 10x, 20x, and 40x objectives. When working with low magnification objectives, the camera will allow you to see the finer details.
Video is recorded at 51.3fps or 133.8fps depending on its resolution. Videos are smooth with soft and subtle transitions between frames. The movement of the sample is displayed in real time with no delays. The camera makes it easy to work with objects that are moving and is suitable for classroom demonstrations.
The camera is equipped with a USB3.0 interface. The data transfer speed is 10 times faster than USB2.0 cameras. The high-speed camera is recommended for professional laboratories, research, or university training.

Microscope head
Tube length – infinity (∞). When assembling the microscope, the user can rotate the eyepiece tubes 180° and adjust eye relief to fit their height. There is a trinocular microscope head.
The monitor is mounted in the vertical tube of the trinocular head and the digital camera – in the camera side port. The light beam on the trinocular head is split 50/50 (tube is open) or 100/0 (tube is closed), on the body – 100/0 or 0/100.

Revolving nosepiece
The 6-objectives revolving nosepiece is mounted on a stand under the stage.

Objectives
Infinity plan achromatic objectives with long working distance for dishes with a bottom thickness of 1.2mm.
Three objectives are intended for brightfield and fluorescence microscopy techniques and the other 3 objectives are for the phase contrast technique.

Focusing mechanism
Coaxial coarse and fine focusing knobs are located at the base of the microscope on both sides. The user can place their hands on the table and take a relaxed pose while observing. The focusing adjustment is smooth and effortless. On the right, there is a coarse focusing lock knob for quick adjustments after changing the specimen. On the left, there is a coarse tension adjustment ring for further adjustment.

Stage
There is a fixed stage with a mechanical attachment for moving the laboratory ware in two mutually perpendicular directions. The smooth and subtle movement of the object augments the accuracy of the study – no part of the specimen will be overlooked. The travel knob is located at the bottom and so the user will not strain their right hand. The microscope set includes four dish holders for dishes of different sizes.

Reflected light illuminator
The fluorescence excitation source is a 100W mercury lamp. It is extremely bright and has a wide spectrum of wavelengths. The mercury lamp has discrete peaks, allowing you to work with many fluorochromes.
The reflected light illuminator contains four excitation filters: ultraviolet (UV), violet (V), blue (B), and green (G).
The mercury lamp is located in the lamphouse and can be centered in three planes. The heat radiation is conducted away from the lamphouse and, therefore, the lamp does not get too hot. The mount allows for safe and quick lamp replacement.

Condenser
Phase contrast turret condenser with four positions. There is a free slot for brightfield microscopy; the other three slots with phase annuli plates are used for working with objectives at magnifications of 10x, 20x, and 40x. The phase contrast rings can be centered. Fast and intuitive switching between microscopy techniques saves time and simplifies the researcher’s work.

Reflected light source
The reflected light illuminator has a 30W halogen bulb. Halogen bulbs emit light with a color temperature that allows for comfortable work. The 30W bulb is bright enough to observe with all the objectives that are used for brightfield and phase contrast microscopy techniques.

Köhler illumination in transmitted light
The Köhler illuminator improves the image quality of the observed sample: Each objective achieves maximum resolution. The field of view is illuminated evenly without darkening at the edges. The object of study is in sharp focus and the image artifacts are removed.

Accessories
There is a line of accessories designed specifically for this microscope.
Eyepieces that extend the magnification range of the microscope. The optional eyepieces help you maximize the potential of the objective that you use most often.
A digital camera that outputs the microscope image on a monitor and stores files along with software that takes real-time measurements of specimens.
A calibration slide for measuring objects that can be combined with an eyepiece with a scale or the camera software.

Key features

Key features of the microscope:
  • Study of specimens in laboratory ware emitting fluorescence when exposed to excitation light
  • Microscopy techniques: fluorescence in reflected light, brightfield, and phase contrast in transmitted light
  • Köhler illumination setup
  • Tiltable stand for dishes up to 165mm
  • Trinocular head with the option to adjust eye relief
  • Two options for mounting a digital camera and monitor: vertical tube of the trinocular head and camera side port on the body; 50/50 and 100/0 beam splitting on the trinocular head, and 100/0 and 0/100 on the body
  • Reflected light illuminator: 100W mercury lamp of a wide wavelength spectrum
  • Fluorescence filters: ultraviolet (UV), violet (V), blue (B), green (G)
  • Phase-contrast turret condenser for quick and convenient changing of the microscopy technique
  • Transmitted light illuminator – 30W halogen bulb providing bright natural light
  • Wide range of compatible optional accessories

Key features of the camera:
  • For fluorescence and darkfield microscopy with 4x, 10x, 20x, or 40x objectives
  • 7.1MP resolution: When observing with low magnification objectives, the camera will enable you to see finer details
  • 51.3fps and 133.8fps at 3200x2200px and 1584x1100px resolutions for observing moving objects, recording video and moving the preparation without jerkiness and delays
  • Peltier element reduces the sensor temperature during prolonged operation and eliminates thermal noise and, therefore, long shutter speeds can be used when taking photos
  • Global shutter for fast signal readout from the sensor, increased image brightness, no false optical effects when observing moving objects
  • SONY Exmor monochrome CMOS backlit sensor provides low noise level and high light sensitivity even in low-light conditions. You will get clearer, brighter, and more color-saturated images
  • USB3.0 interface for fast, smooth data transfer
  • Software with photo, video recording, editing, external display functions, linear and angular measurements

Package

  • MAGUS CLM90 Digital Camera (digital camera, USB cable, 12V, 3A adapter, case, installation CD with drivers and software, user manual and warranty card)
  • Base with a power input, transmitted light source and condenser, focusing mechanism, stage, and revolving nosepiece
  • Fluorescence units
  • Mercury lamphouse
  • Trinocular head
  • Infinity plan achromatic objective: PLL 10x/0.25 WD 4.3mm
  • Infinity plan achromatic objective: PLL 20х/0.40 WD 8.0mm
  • Infinity plan achromatic objective: PLL 40х/0.60 WD 3.5mm
  • Infinity plan achromatic objective: PLL 10x/0.25 PHP2 WD 4.3mm
  • Infinity plan achromatic objective: PLL 20x/0.40 PHP2 WD 8.0mm
  • Infinity plan achromatic objective: PLL 40x/0.60 PHP2 WD 3.5mm
  • Eyepiece 10x/22mm with long eye relief (2 pcs.)
  • UV shield
  • C-mount adapter 1x
  • Hex key wrench
  • Mercury lamphouse power supply
  • Power cord
  • Reflected light illuminator power cord
  • Dust cover
  • User manual and warranty card

Available on request:

Microscope specifications

Microscope design: inverted

Image field: flat-field

Reflected light microscopy techniques: fluorescence

Transmitted light microscopy techniques: brightfield, phase contrast

Microscope magnification, x: 100–400 basic configuration (*optional: 100–500/600/800/1000)

Tube length: infinity (∞)

Microscope head type: trinocular

Microscope head: Siedentopf, rotatable 180°

Inclination: 45°

Microscope head magnification, x: 1

Interpupillary distance, mm: 48–75

Eyepiece diameter, mm: 30

Eyepieces, x/field, mm: 10х/22mm, eye relief: 10mm (*optional: 10x/22mm with a scale, 12.5x/14; 15x/15; 20x/12; 25x/9)

Revolving nosepiece: 6 objectives

Optical design: infinity plan achromatic objectives (∞), parfocal distance: 45mm

Objectives, x/aperture/working distance, mm: PLL 10x/0.25/4.3; PLL 20x/0.40/8.0; PLL 40x/0.60/3.5; phase: PLL 10x/0,25/4,3 PHP2; PLL 20x/0.40/8.0 PHP2; PLL 40x/0.60/3.5 PHP2

Spring-loaded retractable assembly: 40x

Stage: 227x208mm, fixed, with mechanical attachment and glass plates Ø118mm; dish holders: 86x129.5mm, Ø90mm; 34x77.5mm, Ø68.5mm; 57x82mm, Ø60mm; 29x77.5mm, Ø35mm

Moving range, mm: 77/134.5

Condenser: NA 0.6, working distance: 55mm; phase contrast turret; with locking screws.

Field diaphragm: adjustable iris diaphragm

Focusing mechanism: coaxial coarse and fine focusing knobs located on both sides

Fine focusing scale value, μm: 2

Coarse focusing tension adjusting knob: +

Coarse focusing lock knob: +

Illumination: transmitted and reflected light

Reflected light source: mercury lamp 100W

Transmitted light source: 12V, 30W halogen bulb, brightness-adjustable

Fluorescence filter: filter type, excitation wavelength/dichroic mirror/emission wavelength: ultraviolet (UV), 320–380nm/425nm/435nm; violet (V), 380–415nm/455nm/475nm; blue (B), 450–490nm/505nm/515nm; green (G), 495–555nm/585nm/595nm

Phase contrast device: phase contrast condenser (turret) with a free slot and phase annuli plates for 10x, 20x and 40x objectives; centering telescope

Power supply, V/Hz: AC power supply, 85–265/50/60

Operating temperature range, °C (°F): 5… 35 (41… 95)

Operating humidity range, %: 20… 80

Camera specifications

Sensor: SONY Exmor CMOS

Color/monochrome: monochrome

Megapixels: 7.1

Maximum resolution, pix: 3200x2200

Sensor size: 1.1" (14.4x9.9mm)

Pixel size, μm: 4.5x4.5

Two-stage thermoelectric module (Peltier element) to set the temperature 42°C below room temperature: +

Light sensitivity: 3354mV with 1/30s

Signal/noise ratio: 0.15mV with 1/30s

Exposure: 0.1ms–1h

Video recording: +

Frame rate, fps at resolution: 51.3@3200x2200; 133.8@1584x1100; ADC digit capacity (bit); 8/12 (selectable)

Place of installation: trinocular tube

Image format: *.jpg, *.bmp, *.png, *.tif

Video format: recording: *.wmv, *.avi, *.h264 (Win 8 or newer), *h265 (Win 10 or newer)

Spectral range, nm: 380–650 (with anti-reflective filter)

Shutter type: global shutter

White balance: auto/manual

Exposure control: auto/manual

Software features: image size, brightness, exposure time

Output: USB3.0, 5Gb/s

System requirements: Windows 8/10/11 (32 and 64 bit), Mac OS X, Linux, up to 2.8GHz Intel Core 2 or higher, minimum 2GB RAM, USB3.0 port, CD-ROM, 17" or larger display

Software: MAGUS View

Mount type: C-mount

Body: CNC aluminum alloy

Power supply: DC, 5V, from computer USB port; a 12V, 3A adapter for Peltier element

Operating temperature range, °C (°F): –10... 50 (14... 122)

Operating humidity range, %: 30… 80