Digital camera
The digital camera mounted in the trinocular tube using a C-mount adapter will record the intermediate and final results of the observation process. This feature is used for quality control and building a database. The 21MP camera on the 1x C-mount adapter will deliver the desired resolution for stereomicroscope observations, and the 4/3" sensor will display the maximum possible field of view. With the minimum magnification of the microscope, the field of view on the computer screen will be 53.5x37mm.
Microscope head
The zoom objective allows for the smooth change of magnification up to 8.4x with no loss of focus. The microscope generates an upright (not inverted) three-dimensional image. The 0.5x auxiliary objective lens changes the magnification range, field of view, and working distance of the microscope.
A magnification of 3.25–27.5x and a working distance of 177mm for soldering are achieved when the 0.5x auxiliary lens is used.
A magnification of 6.5–55x and a working distance of 105mm for quality control are achieved when the 0.5x auxiliary lens is not used.
Instrument manipulations require a larger field of view than visual observation in quality control. When viewed through the eyepieces, the diameter of the field of view with the 0.5x auxiliary lens is 67.7mm using 3.25x microscope magnification, and it is 8mm using 27.5x magnification.
The basic configuration includes 10x/22mm eyepieces with diopter adjustment and eye relief to work with glasses.
Illuminators
Different tasks require different types of illumination. The kit includes two illuminators. The ring light with a polarizer removes glare from metal. The gooseneck light creates shadows that enable our vision to detect surface topography.
Stand
The universal stand with a solid base minimizes the vibrations that are caused by movement, while the long horizontal arm expands the working area.
It is not always convenient to move the object in the optical path during work. Sometimes moving the microscope head is preferable. The micro adjustment knob allows for the smooth horizontal movement of the microscope head back and forth.
At the end of the stand, there is a mechanism to change the angle of the optical axis. The operator can observe the specimen that is on the table, looking at it from an angle. This feature makes it more convenient to perform manipulations, check the soldering quality, and observe curved objects.
Focusing mechanism
The focusing mechanism has coarse and fine focusing features. The fine focusing will make it easy to adjust the microscope when using magnifications above 40x. The focusing knobs are coaxial, i.e., located on both sides. The coarse focusing tension is adjustable.
Accessories and other off-the-shelf solutions
Comfortable work conditions improve operator productivity. Our off-the-shelf solutions are based on the experience of electronic engineers. At the same time, MAGUS offers other components that you can use to assemble the microscope kit based on your budget and preferences as well as tasks the to be solved. Moreover, in the future, you can supplement the kit with the required accessories.
Key features
Microscope features:- Trinocular microscope head with a vertical tube for mounting a camera
- The zoom lens allows for a smooth magnification change with no loss of focus; 8.4:1 zoom ratio
- The advantages of the Greenough optical design: large depth of field, high-resolution 3D visualization, compact design, and reasonable price
- The 0.5x auxiliary objective lens enables additional options of magnification, field of view, and working distance
- The universal stand expands the working area, allowing for the precise positioning of the microscope head above the specimen and the fine micro adjustment of the head position
- The focusing mechanism has coarse and fine focusing features: Operation is comfortable over the entire magnification range of the microscope
- Two reflected light illuminators: ring light with a polarization filter and a gooseneck light.
- Components may be replaced and additional accessories may be installed upon your request.
Camera features:- The 21MP sensor provides the best resolution for stereomicroscopic observation
- The 4/3" sensor will display the largest possible field of view on the screen
- 17fps at maximum resolution is enough for focus adjustment
- Up to 192fps at reduced resolution is for classroom presentations and video recording; smooth movement of specimens with no jerking or lagging
- SONY Exmor backlit color CMOS sensor delivers low noise performance and high light sensitivity even in low light conditions: clearer, brighter, and more color-saturated images
- USB3.0 interface for fast data transfer with no jerking or lagging
- The software features functions for photography, video recording, editing, external monitor display, and linear and angular measurement
- The included 1x C-mount adapter with adjustable focus distance is used to mount a camera on the microscope
Package
- MAGUS CBF70 digital camera (digital camera, USB cable, storage device with drivers and software, user manual and warranty card)
- MAGUS Stereo 8TH microscope head – objective part and eyepiece tubes
- 10х/22mm eyepiece with eye relief and diopter adjustment (2 pcs.)
- MAGUS UT2 Microscope Stand
- MAGUS FM3 Focus Mount
- MAGUS LED RP1 Ring Light with polarizer
- MAGUS LED DGL2 Dual Gooseneck Light
- MAGUS AL05 0.5х/177mm Auxiliary Lens
- MAGUS ZFA100 C-mount Adapter
- User manual and warranty card
Available on request:- 10x/22mm eyepiece with a scale
- 15x/16mm eyepiece (2 pcs.)
- 20x/12mm eyepiece (2 pcs.)
- 25x/9mm eyepiece (2 pcs.)
- 30x/8mm eyepiece (2 pcs.)
- Auxiliary objective lens 1.5x
- Auxiliary objective lens 2x
- Ring light
- Ring light with sector switching
- HDMI digital camera
- LCD Monitor
- 0.5x C-mount adapter with an adjustable focus distance
- Calibration slide
Microscope specifications
Microscope design: upright
Image field: stereo
Microscopy technique: brightfield
Optical design: Greenough
Microscope head diameter, mm: 76
Magnification, x: 6.5–55; with 0.5x auxiliary objective lens: 3.25–27.5
Microscope head type: trinocular
Inclination: 45°
Interpupillary distance, mm: 54–75
Eyepiece diameter, mm: 30
Diopter adjustment: ±5D on each eyepiece
Eyepieces, x/field, mm: 10x/22, eye relief (*optional: 10x/22mm with a scale, 15x/16, 20х/12, 25x/9, 30x/8)
Zoom objective, x/working distance, mm/field of view with 10x eyepiece, mm: 0.65–5.5/105/33.8–4; with 0.5x auxiliary objective lens: 0.325–2.75/177/67.7–8 (*optional: when using additional eyepieces and objective lenses: 3.25–33/177, 47, 26/67.7–0.9)
Zoom ratio: 8.4:1
Focusing mechanism: coaxial coarse and fine focusing knobs on both sides
Coarse focusing travel, mm: 45
Fine focusing scale value, μm: 2
Coarse focusing tension adjusting knob: +
Horizontal arm diameter, mm: 38
Horizontal arm length, mm: 470
Vertical arm diameter, mm: 38
Vertical arm length, mm: 493
Horizontal travel range of the stand, mm: 380
Maximum height of the specimen, mm: 150 (when no auxiliary objective lenses are used); 65 (when a 0.5x auxiliary objective lens is used)
Mounting pin diameter, mm: 32
Stand base dimensions, mm: 252x252x30
Illumination method: reflected light
Reflected light source: ring light with a polarization filter and adjustable brightness; gooseneck light with adjustable brightness
Available auxiliary objective lenses, x: 1.5; 2
Power supply, V/Hz: AC power supply, 115–230/50/60
Operating temperature range, °C: 0… 40
Operating humidity range, %: 20… 85
Camera specifications
Sensor: SONY Exmor CMOS
Color/monochrome: color
Megapixels: 21
Maximum resolution, px: 5280x3954
Sensor size: 4/3" (17.4x13.0mm)
Pixel size, μm: 3.3x3.3
Light sensitivity: 399mV at 1/30s
Signal/noise ratio: 0.1mV at 1/30s
Exposure: 0.1ms–15s
Video recording: +
Frame rate, fps at resolution: 17@5280x3954; 17@3952x3952; 56@2640x1976; 67@1760x1316; 192@584x438
Place of installation: trinocular tube, eyepiece tube instead of an eyepiece
Image format: *.jpg, *.bmp, *.png, *.tif
Video format: *.wmv, *.avi, *.h264 (Win 8 or newer), *h265 (Win 10 or newer)
Spectral range, nm: 380–650 (with IR filter)
Shutter type: ERS (electronic rolling shutter)
White balance: auto/manual
Exposure control: auto/manual
Software features: image size, brightness, exposure time
Output: USB3.0, 5Gbps
System requirements: Windows 8/10/11 (32 and 64 bit), Mac OS X, Linux, up to 2.8GHz Intel Core 2 or higher, minimum 2GB of RAM, USB3.0 port, CD-ROM, 17" or larger display
Software: MAGUS View
Mount type: C-mount
Body: solid aluminum
Power supply: DC current, 5V, with the USB port of the PC
Operating temperature range, °C: –10... 50
Operating humidity range, %: 30… 80